{"id":6645,"date":"2024-06-19T00:03:18","date_gmt":"2024-06-19T00:03:18","guid":{"rendered":"https:\/\/jash.co.ke\/?post_type=product&#038;p=6645"},"modified":"2024-06-19T00:03:19","modified_gmt":"2024-06-19T00:03:19","slug":"1o-3o-phase-analog-pump-protection-relay","status":"publish","type":"product","link":"https:\/\/jash.co.ke\/index.php\/product\/1o-3o-phase-analog-pump-protection-relay\/","title":{"rendered":"1\u00d8 &#038; 3\u00d8 PHASE ANALOG PUMP PROTECTION RELAY"},"content":{"rendered":"<h2 class=\"subHeading\">BRIEF\u00a0<strong>SPECIFICATIONS<\/strong><\/h2>\n<div class=\"table-responsive\">\n<table class=\"table table-bordered table-striped&gt;&lt;tbody&gt;&lt;tr class=\">\n<tbody>\n<tr>\n<td class=\"a-left\">Measuring Parameter<\/td>\n<td class=\"a-left\">Monitors Over Load (As per NEMA Curve), Over Current, Under Current \/ Dry run, Locked current, Over voltage, Under Voltage, Phase failure<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Electrical Connection<\/td>\n<td class=\"a-left\">1\u00d8 &#8211; 2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Test \/ Reset<\/td>\n<td class=\"a-left\">Manual \/ Auto reset<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">LED Indication<\/td>\n<td class=\"a-left\">Power ON, Current and Voltage parameter<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Voltage Measuring Range<\/td>\n<td class=\"a-left\">180 to 300V AC (L &#8211; N)<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Power Consumption<\/td>\n<td class=\"a-left\">40VA (max)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Motor Rated Current Measuring<\/td>\n<td class=\"a-left\">1A to 30A<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Output Contact<\/td>\n<td class=\"a-left\">Control Output 1 NO Relay,<br \/>\nRelay Rating 30A@277V AC<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">\nAccuracy<\/td>\n<td class=\"a-left\">Current Accuracy \u00b15% of rated current,<br \/>\nVoltage Accuracy \u00b11% of 300V,<br \/>\nTime Accuracy \u00b15% \u00b1100msec<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">\n<p>Functional Specifications<\/td>\n<td class=\"a-left\">Over Load NEMA class 5, 10, 15, 20, 30,<br \/>\nOver Current Ranges 10% &#8211; 70% of Ir (Rated Current),<br \/>\nUnder Current 20% &#8211; 80% of Ir (Rated Current),<br \/>\nLocked Current \/ Stall Current Fixed : 300% of Ir (Rated Current),<br \/>\nOver Voltage Fixed (280V),<br \/>\nUnder Voltage Fixed (180V),<br \/>\nPhase Loss Yes (&lt;160V)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">\n<p>Time Setting<\/td>\n<td class=\"a-left\">Power ON Delay 1sec (Fixed)Trip Time Delay 0, 2, 4, 6, 8 &amp; 10 sec,<br \/>\n(Current &amp; Voltage parameters),<br \/>\nAuto Reser Time 15min,<br \/>\n(Current &amp; Voltage parameters),<br \/>\nPhase Loss Trip Time Instantaneous (&lt;120ms)<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Auto Restart Attempts<\/td>\n<td class=\"a-left\">3 (Fixed)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Mounting<\/td>\n<td class=\"a-left\">DIN Rail Mount<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Size<\/td>\n<td class=\"a-left\">DIN 66.50 x 70 x 90 (H x W x L)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Analog PPR for 3P-3W and 1P-2W systems, 1 C\/O (SPDT) or 1 C\/O (SPST) relay, Voltage Measuring Range : 280V AC to 500V AC (L &#8211; L) or 180 -300V AC<\/p>\n<div class=\"prd-block_title-wrap\">\n<div class=\"product-sku\">Product:\u00a0<span class=\"\">PPRA<\/span><\/div>\n<\/div>\n<div class=\"prd-block_description topline\">\n<ul>\n<li>Monitors: Phase loss, Phase unbalance, Phase sequence, Overload trip current, Under \/ Over current in 1\u00d8 and 3\u00d8 Pumps.<\/li>\n<li>1 C\/O SPDT relay.<\/li>\n<li>Auto \/ Remote test available.<\/li>\n<li>MPCT range : 10A &#8211; 80A<\/li>\n<li>Operating range : 280 -500V AC<\/li>\n<\/ul>\n<p><a class=\"button\" href=\"https:\/\/www.selec.com\/viewdocument\/e58cc5ca94270acaceed13bc82dfedf7\" target=\"_blank\" rel=\"noopener\"> Data Sheet<\/a>\n<\/div>\n","protected":false},"featured_media":6646,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_ti_tpc_template_sync":false,"_ti_tpc_template_id":""},"product_cat":[222],"product_tag":[],"class_list":["post-6645","product","type-product","status-publish","has-post-thumbnail","product_cat-analog-pump-protection-relay","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product\/6645","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/comments?post=6645"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/media\/6646"}],"wp:attachment":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/media?parent=6645"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product_cat?post=6645"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product_tag?post=6645"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}