{"id":6653,"date":"2024-06-19T00:14:20","date_gmt":"2024-06-19T00:14:20","guid":{"rendered":"https:\/\/jash.co.ke\/?post_type=product&#038;p=6653"},"modified":"2024-06-19T00:14:20","modified_gmt":"2024-06-19T00:14:20","slug":"1o-digital-pump-protection-relay-with-inbuilt-wlc","status":"publish","type":"product","link":"https:\/\/jash.co.ke\/index.php\/product\/1o-digital-pump-protection-relay-with-inbuilt-wlc\/","title":{"rendered":"1\u00d8 DIGITAL PUMP PROTECTION RELAY WITH INBUILT WLC"},"content":{"rendered":"<h2 class=\"subHeading\">BRIEF\u00a0<strong>SPECIFICATIONS<\/strong><\/h2>\n<div class=\"table-responsive\">\n<table class=\"table table-bordered table-striped&gt;&lt;tbody&gt;&lt;tr class=\">\n<tbody>\n<tr>\n<td class=\"a-left\">Measuring Parameter<\/td>\n<td class=\"a-left\">Monitors Dry\/Under Current, Over Current, Locked Current, Over Voltage, Under Voltage, Phase Failure and Overload with Automatic start &amp; stop as per water level detection (Float switch)<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Electrical Connection<\/td>\n<td class=\"a-left\">1\u00d8 &#8211; 2<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Test \/ Reset<\/td>\n<td class=\"a-left\">Manual \/ Auto reset<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">LED Indication<\/td>\n<td class=\"a-left\">Power ON, Trip indication<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Display<\/td>\n<td class=\"a-left\">3 Digits, 7 Segment LED display<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Voltage Measuring Range<\/td>\n<td class=\"a-left\">180 to 300V AC (L &#8211; N)<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Power Consumption<\/td>\n<td class=\"a-left\">40VA (max)<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Power Motor Rated Current Measuring<\/td>\n<td class=\"a-left\">1A to 30A<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Output Contact<\/td>\n<td class=\"a-left\">Control Output 1 NO Relay,<br \/>\nRelay Rating 32A@277V AC<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">\nAccuracy<\/td>\n<td class=\"a-left\">Current Accuracy \u00b15% of rated current,<br \/>\nVoltage Accuracy \u00b11% of 300V,<br \/>\nTime Accuracy \u00b15% \u00b1100msec<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">\n<p>Functional Specifications<\/td>\n<td class=\"a-left\">Over load NEMA class 5, 10, 15, 20, 30,<br \/>\nOver current ranges [Ir (Rated current) + 1 to 32A],<br \/>\nUnder current [0.2A to Ir (Rated current) &#8211; 1],<br \/>\nLocked current \/ Stall current [Ir (Rated current) + 1 to 32A],<br \/>\nOver voltage 180V &#8211; 300V AC ( L &#8211; N ),<br \/>\nUnder voltage 180V &#8211; 300V AC ( L &#8211; N )<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">\n<p>Time Setting<\/td>\n<td class=\"a-left\">Power ON delay 1sec (Fixed),<br \/>\nTrip time delay (Current &amp; Voltage parameters) 0 &#8211; 999sec,<br \/>\nRecovery time (Current &amp; Voltage parameters) 1 &#8211; 999sec,<br \/>\nReset attempts 3 (fixed),<br \/>\nReset Attempt Time Frame 1 &#8211; 999 mins<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Auto Restart Attempts<\/td>\n<td class=\"a-left\">3 (Fixed)<\/td>\n<\/tr>\n<tr class=\"even\">\n<td class=\"a-left\">Mounting<\/td>\n<td class=\"a-left\">DIN Rail Mount<\/td>\n<\/tr>\n<tr class=\"odd\">\n<td class=\"a-left\">Size<\/td>\n<td class=\"a-left\">66.50 x 70 x 90 (H x W x L)<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Digital PPR along with WLC for 1P-2W systems, 1 NO relay, Voltage Measuring Range 180 to 300V AC (L &#8211; N)<\/p>\n<div class=\"prd-block_title-wrap\">\n<div class=\"product-sku\"><strong>Product<\/strong>:\u00a0<span class=\"\">PPRWD-4M-1<\/span><\/div>\n<\/div>\n<div class=\"prd-block_description topline\">\n<ul>\n<li>Monitors: Phase loss, Phase unbalance, Phase sequence, Overload trip current, Under \/ Over current and voltage in 1\u00d8 pumps.<\/li>\n<li>Float switch Input for water level based pump controlling<\/li>\n<li>Auto \/ Remote test available.<\/li>\n<li>Output contact : 1 SPST relay , Direct 30A Relay output.<\/li>\n<li>Direct 30A Relay output.<\/li>\n<li>Aux Supply : 180 to 300V AC (L-N)<\/li>\n<\/ul>\n<p><a class=\"button\" href=\"https:\/\/www.selec.com\/viewdocument\/20d135f0f28185b84a4cf7aa51f29500\" target=\"_blank\" rel=\"noopener\"> Data Sheet<\/a>\n<\/div>\n","protected":false},"featured_media":6652,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_ti_tpc_template_sync":false,"_ti_tpc_template_id":""},"product_cat":[223],"product_tag":[],"class_list":["post-6653","product","type-product","status-publish","has-post-thumbnail","product_cat-digital-pump-protection-relay","first","instock","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product\/6653","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/comments?post=6653"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/media\/6652"}],"wp:attachment":[{"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/media?parent=6653"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product_cat?post=6653"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/jash.co.ke\/index.php\/wp-json\/wp\/v2\/product_tag?post=6653"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}